{"id":37189,"date":"2026-09-01T13:21:25","date_gmt":"2026-09-01T11:21:25","guid":{"rendered":"https:\/\/jettools.de\/produkt\/dynacut-2-176-en\/"},"modified":"2026-10-24T14:57:38","modified_gmt":"2026-10-24T12:57:38","slug":"dynacut-2-176-en","status":"publish","type":"product","link":"https:\/\/jettools.de\/en\/produkt\/dynacut-2-176-en\/","title":{"rendered":"DYNACUT minimum quantity lubrication system MDA-SV"},"content":{"rendered":"<p>The DYNACUT MDA-SV has a V-nozzle for application on both sides at band and circular saws, with the hoses in a protective sleeve. Like all systems of the MDA series, it works as droplet lubrication with a coaxial spray nozzle for external lubrication in cutting and forming processes, especially for aluminium machining.<\/p>\n<p>Lubricant and air remain separate up to the nozzle and are metered via needle valves. The reservoir pressure is set via a hand valve to 0.3\u20131.5 bar depending on viscosity. Air and lubricant are switched via solenoid valves, electric control is possible for example via the CNC. The valves are available for 230 V AC, 24 V AC or 24 V DC.<\/p>\n<p>The unit is made entirely of aluminium, the capacity is 2.0 l, consumption is 0\u2013100 ml\/h with an air consumption of 25\u201350 l\/min per outlet. The inlet pressure is min. 2.5 bar to max. 8 bar, the operating pressure max. 2 bar. The system has 1\u20132 outlets, a 6 mm compressed air connection and weighs 4.5 kg.<\/p>\n<p>The DYNACUT MDA-SV is supplied with v-nozzle for band and circular saws, Protective sleeve for connecting hoses and operating manual. Lubricant is not included, only lubricants approved for MQL may be used.<\/p>\n<h3>Features at a glance<\/h3>\n<ul>\n<li>V-nozzle for application on both sides at band and circular saws, hoses in a protective sleeve<\/li>\n<li>Coaxial spray nozzle, lubricant and air separate up to the nozzle<\/li>\n<li>Solenoid valves 230 V AC \/ 24 V AC \/ 24 V DC<\/li>\n<li>All-aluminium, capacity 2.0 l<\/li>\n<li>Consumption 0\u2013100 ml\/h, 1\u20132 outlets<\/li>\n<\/ul>\n<h2>Technical data<\/h2>\n<table>\n<tbody>\n<tr>\n<th colspan=\"2\" style=\"text-align:left;padding-top:10px\">Electrical<\/th>\n<\/tr>\n<tr>\n<td>Solenoid valve voltage<\/td>\n<td>230 V AC \/ 24 V AC \/ 24 V DC (depending on version)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\" style=\"text-align:left;padding-top:10px\">Capacities<\/th>\n<\/tr>\n<tr>\n<td>Version<\/td>\n<td>V-nozzle for application on both sides at band and circular saws, hoses in a protective sleeve<\/td>\n<\/tr>\n<tr>\n<td>Lubrication method<\/td>\n<td>droplet lubrication, low-pressure system with coaxial spray nozzle<\/td>\n<\/tr>\n<tr>\n<td>Lubrication type<\/td>\n<td>external lubrication (total-loss)<\/td>\n<\/tr>\n<tr>\n<td>Control<\/td>\n<td>electric via solenoid valves (e.g. via CNC)<\/td>\n<\/tr>\n<tr>\n<td>Metering<\/td>\n<td>needle valves, lubricant and air kept separate up to the nozzle<\/td>\n<\/tr>\n<tr>\n<td>Lubricant consumption<\/td>\n<td>0\u2013100 ml\/h<\/td>\n<\/tr>\n<tr>\n<td>Air consumption<\/td>\n<td>25\u201350 l\/min per outlet<\/td>\n<\/tr>\n<tr>\n<td>Outlets<\/td>\n<td>1\u20132<\/td>\n<\/tr>\n<tr>\n<td>Inlet pressure<\/td>\n<td>min. 2.5 bar \/ max. 8 bar<\/td>\n<\/tr>\n<tr>\n<td>Operating pressure<\/td>\n<td>max. 2 bar (preset 1 bar)<\/td>\n<\/tr>\n<tr>\n<td>Reservoir pressure<\/td>\n<td>0.3\u20131.5 bar depending on viscosity (pressure regulating\/hand valve)<\/td>\n<\/tr>\n<tr>\n<td>Compressed air connection<\/td>\n<td>6 mm<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\" style=\"text-align:left;padding-top:10px\">Weight<\/th>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>4.5 kg<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\" style=\"text-align:left;padding-top:10px\">Further data<\/th>\n<\/tr>\n<tr>\n<td>Construction<\/td>\n<td>all-aluminium<\/td>\n<\/tr>\n<tr>\n<td>Capacity<\/td>\n<td>2.0 l<\/td>\n<\/tr>\n<tr>\n<td>Reservoir mounting position<\/td>\n<td>vertical<\/td>\n<\/tr>\n<tr>\n<td>Lubricant<\/td>\n<td>not included<\/td>\n<\/tr>\n<tr>\n<td>Permitted lubricants<\/td>\n<td>only lubricants approved for MQL<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Scope of delivery<\/h2>\n<ul>\n<li>DYNACUT MDA-SV minimum quantity lubrication system<\/li>\n<li>V-nozzle for band and circular saws<\/li>\n<li>Protective sleeve for connecting hoses<\/li>\n<li>Operating manual<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The DYNACUT MDA-SV is a minimum quantity lubrication system in aluminium design with droplet lubrication, version SV (V-nozzle for application on both sides at band and circular saws, hoses in a protective sleeve). Consumption 0\u2013100 ml\/h.<\/p>\n","protected":false},"featured_media":51091,"comment_status":"open","ping_status":"closed","template":"","meta":[],"jt_maschine":[],"product_brand":[6569],"product_cat":[6555],"product_tag":[],"class_list":["post-37189","product","type-product","status-publish","has-post-thumbnail","product_brand-dynacut","product_cat-mql-systems","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/jettools.de\/en\/wp-json\/wp\/v2\/product\/37189","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jettools.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/jettools.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/jettools.de\/en\/wp-json\/wp\/v2\/comments?post=37189"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jettools.de\/en\/wp-json\/wp\/v2\/media\/51091"}],"wp:attachment":[{"href":"https:\/\/jettools.de\/en\/wp-json\/wp\/v2\/media?parent=37189"}],"wp:term":[{"taxonomy":"jt_maschine","embeddable":true,"href":"https:\/\/jettools.de\/en\/wp-json\/wp\/v2\/jt_maschine?post=37189"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/jettools.de\/en\/wp-json\/wp\/v2\/product_brand?post=37189"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/jettools.de\/en\/wp-json\/wp\/v2\/product_cat?post=37189"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/jettools.de\/en\/wp-json\/wp\/v2\/product_tag?post=37189"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}