DYNACUT solenoid valve Magnetventil 230 V AC
25,89 € gross21,76 € netincl. VAT · Shipping costs
Optional solenoid valve for DYNACUT lubrication systems. Voltage as specified in the model designation; connection by a qualified electrician only.
Available
Delivery / availability: Approx. 6 working days The period starts after conclusion of the contract or, for agreed prepayment, after your payment instruction.
Overview
Optional solenoid valve for DYNACUT lubrication systems. Voltage as specified in the model designation; connection by a qualified electrician only.
Scope of delivery: 1 unit in the version stated in the model designation. Lubricant is not included. Delivery time approx. 6 working days.
Safety
- Use only as intended on machine tools and only by instructed personnel.
- Operate only at the rated voltage shown on the product.
- Before installation, cleaning, refilling or maintenance, disconnect compressed air and fully depressurise the system; also isolate electrical versions from the power supply.
- Use only lubricants suitable for minimum-quantity lubrication and follow the safety data sheet. Do not use flammable, explosive or incompatible substances.
Downloads
Operating manuals and spare-parts listsProduct safety
- Compressed air and escaping lubricant can cause eye, skin and injection injuries; damaged lines may release suddenly.
- Do not inhale aerosols or oil mist. Mineral-oil aerosols may be harmful; provide effective extraction or adequate ventilation.
- Lubricant mist may be flammable. Exclude ignition sources, open flames, sparks and smoking from the work area.
- Rotating tools, moving machine parts and chips create additional crushing, cutting and entanglement hazards; machine guards must remain effective.
- In the event of leakage, unusual pressure loss, damaged lines, malfunction or unintended discharge, stop the system immediately.
- Incorrect supply voltage, moisture or damaged wiring can cause electric shock, short circuit, fire or unintended actuation.
- Before commissioning, follow the manufacturer information supplied for the product and machine and the lubricant safety data sheet in full.
- Before installation, cleaning, filling, nozzle changes, troubleshooting or maintenance, shut off compressed air, fully depressurise and secure against restart; the pressure gauge must read zero before opening.
- Before every use, inspect reservoir, hoses, connectors, valves, nozzle and mountings for secure seating, wear, kinks, leakage and damage.
- Secure and aim the nozzle so that no person can be struck and no collision with tool, workpiece, clamping device or guard is possible.
- Fill only clean, suitable lubricant; observe labelling, miscibility and the safety data sheet. Collect spills immediately.
- Use the personal protective equipment required by the machining process and lubricant safety data sheet, including suitable eye and skin protection.
- After intervention, test tightness and secure seating at low pressure before bringing the system to operating pressure in a controlled manner.
- Electrical connection may be made only by a qualified electrician using the specified ratings; isolate, lock out and verify absence of voltage before work.
- Use exclusively for external minimum-quantity lubrication of suitable machining and forming processes on machine tools.
- Operate only with lubricants suitable for minimum-quantity lubrication and within the technical limits specified for the particular DYNACUT product.
- Installation, adjustment, operation and maintenance may be performed only by instructed or qualified personnel.
- Before installation, verify product designation, version, connection data and compatibility with the intended machine and DYNACUT system.
- Use electrical accessories only for their intended switching function with compatible DYNACUT components and the correct rated voltage.
- Do not point at persons or animals and do not use for body care, room treatment, food applications or breathing air.
- Do not fill or convey hazardous or incompatible media, especially petrol, nitro thinner, concentrated acids, chlorinated hydrocarbons or solutions containing more than 30% alcohol.
- Do not operate in explosive atmospheres or near open flames, sparks, glowing materials or hot surfaces.
- Never exceed the permitted pressure, electrical ratings or media compatibility and never bypass safety devices.
- Do not make unauthorised modifications or use untested spare parts or unapproved combinations.
- Collect lubricant residues, cleaning fluids and contaminated absorbents and dispose of them in accordance with the safety data sheet and local rules; do not release them into drains, soil or water.
- Fully depressurise the product before dismantling or disposal and secure residual media in a suitable labelled container.
- Separate metal, plastic and packaging components for recycling where permitted.
- Dispose of electrical or electronic components separately from household waste through the designated collection system.
Manufacturer
Dynacut UG (haftungsbeschränkt)Barbarastr. 1648734 RekenGermanyEU economic operator
ToolParts-GroupKleinhaslach 3590599 DietenhofenGermanyService & spare parts
Technical documents, spare-parts identification and repair support remain permanently available through ToolParts-Service.
Open technical service