TODAY’S HIGHLIGHTS
--HOURS--MINUTES--SECONDS

New selection at midnight (German time). While stocks last.

DYNACUT minimum quantity lubrication system MVE

Item number1-130

228,90 € gross192,35 € netincl. VAT · Shipping costs

The DYNACUT MVE is a minimum quantity lubrication system with mist lubrication and solenoid valves for electric control, e.g. via the CNC. Consumption 0–100 ml/h, valve voltage 230 V.

Available

Delivery / availability: Approx. 6 working days The period starts after conclusion of the contract or, for agreed prepayment, after your payment instruction.

Customer groupPurchase: businesses and private customers

In use

DYNACUT minimum quantity lubrication system MVE – In use

Overview

The DYNACUT MVE delivers lubricant as a fine mist directly to the friction point between tool and workpiece. It works as a total-loss system and is intended exclusively for external lubrication in cutting and forming processes – as original equipment or for retrofitting on machines with an existing coolant supply.

Using the Venturi principle, compressed air atomises the low-viscosity coolant into mist. Air and coolant quantities are set via needle valves. Air and lubricant are switched via solenoid valves, so the system can be switched on and off electrically, for example via the CNC control. The solenoid valves are connected to 230 V.

The PE reservoir holds 1.5 l, lubricant consumption is 0–100 ml/h. At inlet pressure min. 3 bar / max. 8 bar the system uses 50–80 l/min of air depending on the nozzle setting, the compressed air connection is 6 mm. The weight is 3 kg.

The system is supplied fully assembled and ready for operation with coolant reservoir including suction filter, approx. 3 m connecting hose and spray head with needle valve and flexibly adjustable nozzle. Lubricant is not included, only lubricants approved for MQL may be used.

Features at a glance

  • Mist lubrication using the Venturi principle
  • Solenoid valves for air and lubricant, 230 V
  • Needle valves for air and coolant
  • Consumption 0–100 ml/h, 1–2 outlets
  • Fully assembled and ready for operation

Technical data

Electrical
Solenoid valve voltage230 V
Capacities
Lubrication methodmist lubrication (Venturi principle)
Lubrication typeexternal lubrication (total-loss)
Controlelectric via solenoid valves for air and lubricant (e.g. via CNC)
Meteringneedle valves for air and coolant
Lubricant consumption0–100 ml/h
Outlets1–2
Inlet pressuremin. 3 bar / max. 8 bar
Operating pressuremax. 8 bar
Air consumption50–80 l/min (depending on nozzle setting)
Compressed air connection6 mm
Weight
Weight3 kg
Further data
ReservoirPE plastic
Capacity1.5 l
Reservoir mounting positionvertical
Lubricantnot included
Permitted lubricantsonly lubricants approved for MQL

Scope of delivery

  • DYNACUT MVE minimum quantity lubrication system
  • Coolant reservoir with suction filter
  • Connecting hose approx. 3 m
  • Spray head with needle valve and flexibly adjustable nozzle

Downloads

Operating manuals and spare-parts lists

Product safety

  • Compressed air and escaping lubricant can cause eye, skin and injection injuries; damaged lines may release suddenly.
  • Do not inhale aerosols or oil mist. Mineral-oil aerosols may be harmful; provide effective extraction or adequate ventilation.
  • Lubricant mist may be flammable. Exclude ignition sources, open flames, sparks and smoking from the work area.
  • Rotating tools, moving machine parts and chips create additional crushing, cutting and entanglement hazards; machine guards must remain effective.
  • In the event of leakage, unusual pressure loss, damaged lines, malfunction or unintended discharge, stop the system immediately.
  • Reservoir and lines may remain pressurised after the system has been switched off.
  • Incorrect supply voltage, moisture or damaged wiring can cause electric shock, short circuit, fire or unintended actuation.
  • Before commissioning, follow the manufacturer information supplied for the product and machine and the lubricant safety data sheet in full.
  • Before installation, cleaning, filling, nozzle changes, troubleshooting or maintenance, shut off compressed air, fully depressurise and secure against restart; the pressure gauge must read zero before opening.
  • Before every use, inspect reservoir, hoses, connectors, valves, nozzle and mountings for secure seating, wear, kinks, leakage and damage.
  • Secure and aim the nozzle so that no person can be struck and no collision with tool, workpiece, clamping device or guard is possible.
  • Fill only clean, suitable lubricant; observe labelling, miscibility and the safety data sheet. Collect spills immediately.
  • Use the personal protective equipment required by the machining process and lubricant safety data sheet, including suitable eye and skin protection.
  • After intervention, test tightness and secure seating at low pressure before bringing the system to operating pressure in a controlled manner.
  • Check fill level, pressure setting and spray pattern regularly; never open the reservoir while pressurised.
  • Electrical connection may be made only by a qualified electrician using the specified ratings; isolate, lock out and verify absence of voltage before work.
  • Use exclusively for external minimum-quantity lubrication of suitable machining and forming processes on machine tools.
  • Operate only with lubricants suitable for minimum-quantity lubrication and within the technical limits specified for the particular DYNACUT product.
  • Installation, adjustment, operation and maintenance may be performed only by instructed or qualified personnel.
  • Before installation, verify product designation, version, connection data and compatibility with the intended machine and DYNACUT system.
  • Mount the complete system securely and operate it only with the intended compressed-air, reservoir and nozzle components.
  • Do not point at persons or animals and do not use for body care, room treatment, food applications or breathing air.
  • Do not fill or convey hazardous or incompatible media, especially petrol, nitro thinner, concentrated acids, chlorinated hydrocarbons or solutions containing more than 30% alcohol.
  • Do not operate in explosive atmospheres or near open flames, sparks, glowing materials or hot surfaces.
  • Never exceed the permitted pressure, electrical ratings or media compatibility and never bypass safety devices.
  • Do not make unauthorised modifications or use untested spare parts or unapproved combinations.
  • Collect lubricant residues, cleaning fluids and contaminated absorbents and dispose of them in accordance with the safety data sheet and local rules; do not release them into drains, soil or water.
  • Fully depressurise the product before dismantling or disposal and secure residual media in a suitable labelled container.
  • Separate metal, plastic and packaging components for recycling where permitted.
  • Dispose of electrical or electronic components separately from household waste through the designated collection system.

Service & spare parts

Technical documents, spare-parts identification and repair support remain permanently available through ToolParts-Service.

Open technical service

Zu WhatsApp wechseln?

Beim Fortfahren öffnen Sie WhatsApp. Dabei gelten die Datenschutzbestimmungen von WhatsApp. Alternativ erreichen Sie uns per E-Mail unter info@toolparts-service.biz.

Weiter zu WhatsApp
Withdraw from contract