DYNACUT minimum quantity lubrication system MSA-2

Item number7-180

939,90 € gross789,83 € netincl. VAT · Shipping costs

The DYNACUT MSA-2 is an aluminium pump system with piston pump for minimum quantity lubrication in version MSA-2 with two pumps. Delivery 0.12–39.00 mm³ per stroke, 2.0 l reservoir.

Available

Delivery / availability: Approx. 6 working days The period starts after conclusion of the contract or, for agreed prepayment, after your payment instruction.

Customer groupPurchase: businesses and private customers

In use

DYNACUT minimum quantity lubrication system MSA-2 – In use

Overview

The DYNACUT MSA-2 is the version with two pumps of the MSA series. The complete pump system with coaxial spray nozzle and all-aluminium housing is used for external lubrication in milling, turning and drilling and delivers lubricant directly to the friction point between tool and workpiece.

A pneumatically driven piston pump with pneumatic pulse generator delivers the lubricant: an air pulse pushes the piston forward, a spring returns it. Delivery is infinitely adjusted via the stroke frequency of 5–100 strokes/min and the adjustable piston stroke, the air quantity at the nozzle tip via a needle valve. As standard, control is via ball valve and compressed air connection, optionally via solenoid valve (24 V DC, alternatively 110 / 230 V AC), roller lever valve, hand slide valve or foot pedal.

Delivery is 0.12–39.00 mm³ per piston stroke for lubricants up to 600 cSt with a droplet size of approx. 15–35 µm. The reservoir holds 2.0 l, compressed air may be max. 6 bar. Measuring 161 × 165 × 400 mm with an empty weight of max. 10 kg, the system is designed for an operating temperature of 0–40 °C. Level monitoring is available as an option.

The DYNACUT MSA-2 is supplied with operating manual. Lubricant is not included, only lubricants approved for MQL may be used.

Features at a glance

  • Piston pump with pneumatic pulse generator
  • All-aluminium housing, 2.0 l reservoir
  • 0.12–39.00 mm³ per stroke, 5–100 strokes/min
  • Lubricants up to 600 cSt
  • Optional solenoid valve, roller lever valve, hand slide valve, foot pedal

Technical data

Electrical
Solenoid valve voltage (optional)24 V DC (standard), alternatively 110 / 230 V AC, 3 VA
Capacities
VersionMSA-2 (with two pumps)
Lubrication methodpump system with pneumatically driven piston pump and coaxial spray nozzle
Pump drivecompressed air, pneumatic pulse generator, spring return
Lubrication typeexternal lubrication (total-loss)
Delivery per piston stroke0.12–39.00 mm³
Stroke frequency5–100 strokes/min
Delivery adjustmentinfinitely variable via stroke frequency and adjustable piston stroke
Air quantity adjustmentneedle valve at the nozzle tip
Droplet sizeapprox. 15–35 µm
Lubricant viscosityup to 600 cSt
Compressed airmax. 6 bar
Control (standard)ball valve and compressed air connection
Control (optional)solenoid valve / roller lever valve / hand slide valve / foot pedal
Dimensions
Dimensions (L × D × H)161 × 165 × 400 mm
Weight
Empty weightmax. 10 kg
Further data
Level monitoringoptional
Housingall-aluminium
Reservoir2.0 l
Operating temperature0–40 °C
Reservoir mounting positionvertical
Lubricantnot included
Permitted lubricantsonly lubricants approved for MQL

Scope of delivery

  • DYNACUT MSA-2 minimum quantity lubrication system
  • Operating manual

Downloads

Operating manuals and spare-parts lists

Product safety

  • Compressed air and escaping lubricant can cause eye, skin and injection injuries; damaged lines may release suddenly.
  • Do not inhale aerosols or oil mist. Mineral-oil aerosols may be harmful; provide effective extraction or adequate ventilation.
  • Lubricant mist may be flammable. Exclude ignition sources, open flames, sparks and smoking from the work area.
  • Rotating tools, moving machine parts and chips create additional crushing, cutting and entanglement hazards; machine guards must remain effective.
  • In the event of leakage, unusual pressure loss, damaged lines, malfunction or unintended discharge, stop the system immediately.
  • Reservoir and lines may remain pressurised after the system has been switched off.
  • Incorrect supply voltage, moisture or damaged wiring can cause electric shock, short circuit, fire or unintended actuation.
  • Before commissioning, follow the manufacturer information supplied for the product and machine and the lubricant safety data sheet in full.
  • Before installation, cleaning, filling, nozzle changes, troubleshooting or maintenance, shut off compressed air, fully depressurise and secure against restart; the pressure gauge must read zero before opening.
  • Before every use, inspect reservoir, hoses, connectors, valves, nozzle and mountings for secure seating, wear, kinks, leakage and damage.
  • Secure and aim the nozzle so that no person can be struck and no collision with tool, workpiece, clamping device or guard is possible.
  • Fill only clean, suitable lubricant; observe labelling, miscibility and the safety data sheet. Collect spills immediately.
  • Use the personal protective equipment required by the machining process and lubricant safety data sheet, including suitable eye and skin protection.
  • After intervention, test tightness and secure seating at low pressure before bringing the system to operating pressure in a controlled manner.
  • Check fill level, pressure setting and spray pattern regularly; never open the reservoir while pressurised.
  • Electrical connection may be made only by a qualified electrician using the specified ratings; isolate, lock out and verify absence of voltage before work.
  • Use exclusively for external minimum-quantity lubrication of suitable machining and forming processes on machine tools.
  • Operate only with lubricants suitable for minimum-quantity lubrication and within the technical limits specified for the particular DYNACUT product.
  • Installation, adjustment, operation and maintenance may be performed only by instructed or qualified personnel.
  • Before installation, verify product designation, version, connection data and compatibility with the intended machine and DYNACUT system.
  • Mount the complete system securely and operate it only with the intended compressed-air, reservoir and nozzle components.
  • Do not point at persons or animals and do not use for body care, room treatment, food applications or breathing air.
  • Do not fill or convey hazardous or incompatible media, especially petrol, nitro thinner, concentrated acids, chlorinated hydrocarbons or solutions containing more than 30% alcohol.
  • Do not operate in explosive atmospheres or near open flames, sparks, glowing materials or hot surfaces.
  • Never exceed the permitted pressure, electrical ratings or media compatibility and never bypass safety devices.
  • Do not make unauthorised modifications or use untested spare parts or unapproved combinations.
  • Collect lubricant residues, cleaning fluids and contaminated absorbents and dispose of them in accordance with the safety data sheet and local rules; do not release them into drains, soil or water.
  • Fully depressurise the product before dismantling or disposal and secure residual media in a suitable labelled container.
  • Separate metal, plastic and packaging components for recycling where permitted.
  • Dispose of electrical or electronic components separately from household waste through the designated collection system.

Service & spare parts

Technical documents, spare-parts identification and repair support remain permanently available through ToolParts-Service.

Open technical service

Zu WhatsApp wechseln?

Beim Fortfahren öffnen Sie WhatsApp. Dabei gelten die Datenschutzbestimmungen von WhatsApp. Alternativ erreichen Sie uns per E-Mail unter info@toolparts-service.biz.

Weiter zu WhatsApp
Withdraw from contract